Conditions for sample preparation and quantitative HPLC/MS-MS analysis of bulky adducts to serum albumin with diolepoxides of polycyclic aromatic hydrocarbons as models

Stable adducts to serum albumin (SA) from electrophilic and genotoxic compounds/metabolites can be used as biomarkers for quantification of the corresponding in vivo dose. In the present study, conditions for specific analysis of stable adducts to SA formed from carcinogenic polycyclic aromatic hydr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2014-02, Vol.406 (5), p.1519-1530
Hauptverfasser: Westberg, Emelie, Hedebrant, Ulla, Haglund, Johanna, Alsberg, Tomas, Eriksson, Johan, Seidel, Albrecht, Törnqvist, Margareta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Stable adducts to serum albumin (SA) from electrophilic and genotoxic compounds/metabolites can be used as biomarkers for quantification of the corresponding in vivo dose. In the present study, conditions for specific analysis of stable adducts to SA formed from carcinogenic polycyclic aromatic hydrocarbons (PAH) were evaluated in order to achieve a sensitive and reproducible quantitative method. Bulky adducts from diolepoxides (DE) of PAH, primarily DE of benzo[ a ]pyrene (BPDE) and also DE of dibenzo[ a , l ]pyrene (DBPDE) and dibenzo[ a , h ]anthracene (DBADE), were used as model compounds. The alkylated peptides obtained after enzymatic hydrolysis of human SA modified with the different PAHDE were principally PAHDE-His-Pro, PAHDE-His-Pro-Tyr and PAHDE-Lys. Alkaline hydrolysis under optimised conditions gave the BPDE-His as the single analyte of alkylated His, but also indicated degradation of this adduct. It was not possible to obtain the BPDE-His as one analyte from BPDE-alkylated SA through modifications of the enzymatic hydrolysis. The BPDE-His adduct was shown to be stable during the weak acidic conditions used in the isolation of SA. Enrichment by HPLC or SPE, but not butanol extraction, gave good recovery, using Protein LoBind tubes. A simple internal standard (IS) approach using SA modified with other PAHDE as IS was shown to be applicable. A robust analytical procedure based on digestion with pronase, enrichment by HPLC or SPE, and analysis with HPLC/MS-MS electrospray ionisation was achieved. A good reproducibility (coefficient of variation (CV) 11 %) was obtained, and the achieved limit of detection for the studied PAHDE, using standard instrumentation, was approximately 1 fmol adduct/mg SA analysing extract from 5 mg SA. Figure An outline of the method for analysis of bulky SA-adducts. All steps/conditions were evaluated.
ISSN:1618-2642
1618-2650
1618-2650
DOI:10.1007/s00216-013-7540-7