Durability of District Heating Pipelines Exposed to Thermal Aging and Cyclic Operational Loads
AbstractFourth generation district heating networks (4GDH) must be designed for future energy systems, integrating renewable volatile energy sources, with lower operation temperatures, and consequent reduction of heat losses and increased energy efficiency. The lower levels of operating temperature...
Gespeichert in:
Veröffentlicht in: | Journal of pipeline systems 2021-02, Vol.12 (1) |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AbstractFourth generation district heating networks (4GDH) must be designed for future energy systems, integrating renewable volatile energy sources, with lower operation temperatures, and consequent reduction of heat losses and increased energy efficiency. The lower levels of operating temperature and the greater amount of cyclic loading, influence aging, and the service life of 4GDH pipelines, differently from traditional district heating (DH) networks, and thus require proper investigation of the system response at the cross-sectional level. To evaluate the material durability of 4GDH pipelines, we have analyzed the behavior of the service steel pipe, the insulation foam, and their adhesive interaction, using an innovative analytical and experimental procedure. This paper describes the influence of traditional and future operational loading conditions on the performance of preinsulated bonded single-pipe systems, representing the majority of currently operating DH pipelines. The performed fatigue analysis of the steel service pipe showed that the lifetime of 4GDH pipelines is expected to increase because of the lower operating temperature, and the low impact of thermal loading volatility in the network, compared to conventional DH. The accelerated aging tests of DN 50/160 pipes demonstrated that the combined effect of cyclic mechanical loading and thermal aging accelerates the rate of chemical degradation of the PUR foam, leading to a faster deterioration of the mechanical adhesion strength. The shear strength tests of naturally aged DH pipes revealed that, besides the initial pipe system characteristics and aging period, the residual shear strength of the polyurethane (PUR) foam depends on the temperature history, decreasing with the level of operating temperature and amount of fluctuation. The obtained results give a better understanding of the performance of traditional and 4GDH pipelines in operation that need to be appropriately considered in the engineering design standards of DH networks toward a more sustainable and energy-efficient infrastructure. |
---|---|
ISSN: | 1949-1190 1949-1204 |
DOI: | 10.1061/(ASCE)PS.1949-1204.0000521 |