Intercomparison of ac peak voltage measurement

An intercomparison on the measurement of high voltage peak value has been carried out between the National Metrology Institutes of Sweden and Germany in 1995 and between Finland and Sweden in 1996. The results show a very satisfactory agreement between the participants. It seems that part of the dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bergman, A, Marx, R, Schon, K, Suomalainen, E.-P, Hallstrom, J
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An intercomparison on the measurement of high voltage peak value has been carried out between the National Metrology Institutes of Sweden and Germany in 1995 and between Finland and Sweden in 1996. The results show a very satisfactory agreement between the participants. It seems that part of the discrepancies found may be due to the loose definition of peak voltage in IEC 60060-1. (4 pages)
ISSN:0537-9989
DOI:10.1049/cp:19990495