Exploring the peptide retention mechanism in molecularly imprinted polymers

Molecularly imprinted polymers (MIPs) have been used as useful sorbents in solid-phase extraction for a wide range of molecules and sample matrices. Their unique selectivity can be fine-tuned in the imprinting process and is crucial for the extraction of macromolecules from complex matrices such as...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2017-09, Vol.409 (24), p.5631-5643
Hauptverfasser: Rossetti, Cecilia, Ore, Odd Gøran, Sellergren, Börje, Halvorsen, Trine Grønhaug, Reubsaet, Léon
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Molecularly imprinted polymers (MIPs) have been used as useful sorbents in solid-phase extraction for a wide range of molecules and sample matrices. Their unique selectivity can be fine-tuned in the imprinting process and is crucial for the extraction of macromolecules from complex matrices such as serum. A relevant example of this is the application of MIPs to peptides in diagnostic assays. In this article the selectivity of MIPs, previously implemented in a quantitative mass-spectrometric assay for the biomarker pro-gastrin-releasing peptide, is investigated. Partial least squares regression was used to generate models for the evaluation and prediction of the retention mechanism of MIPs. A hypothesis on interactions of MIPs with the target peptide was verified by ad hoc experiments considering the relevant peptide physicochemical properties highlighted from the multivariate analysis. Novel insights into and knowledge of the driving forces responsible for the MIP selectivity have been obtained and can be directly used for further optimization of MIP imprinting strategies. Graphical Abstract Applied analytical strategy: the Solid Phase Extraction (SPE) of digested Bovin Serum Albumin (BSA), using Molecularly Imprinted Polymers (MIP), is followed by the liquid chromatography-mass spectrometry (LC-MS) analysis for the identification of the retained peptides. The further application of multivariate analysis allows setting up a Partial Least Square (PLS) model, which describes the peptide retention into the MIP and gives additional knowledge to be used in the optimization of the MIP and the whole SPE method
ISSN:1618-2642
1618-2650
1618-2650
DOI:10.1007/s00216-017-0520-6