Material mapping strategy to improve the predicted response of the proximal femur to a sideways fall impact

Sideways falls are largely responsible for the highly prevalent osteoporotic hip fractures in today's society. These injuries are dynamic events, therefore dynamic FE models validated with dynamic ex vivo experiments provide a more realistic simulation than simple quasi-static analysis. Drop to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the mechanical behavior of biomedical materials 2018-02, Vol.78, p.196-205
Hauptverfasser: Enns-Bray, W S, Bahaloo, H, Fleps, I, Ariza, O, Gilchrist, S, Widmer, R, Guy, P, Pálsson, H, Ferguson, S J, Cripton, P A, Helgason, B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Sideways falls are largely responsible for the highly prevalent osteoporotic hip fractures in today's society. These injuries are dynamic events, therefore dynamic FE models validated with dynamic ex vivo experiments provide a more realistic simulation than simple quasi-static analysis. Drop tower experiments using cadaveric specimens were used to identify the material mapping strategy that provided the most realistic mechanical response under impact loading. The present study tested the addition of compression-tension asymmetry, tensile bone damage, and cortical-specific strain rate dependency to the material mapping strategy of fifteen dynamic FE models of the proximal femur, and found improved correlations and reduced error for whole bone stiffness (R = 0.54, RSME = 0.87kN/mm) and absolute maximum force (R = 0.56, RSME =0.57kN), and a high correlation in impulse response (R = 0.82, RSME =12.38kg/s). Simulations using fully bonded nodes between the rigid bottom plate and PMMA cap supporting the femoral head had higher correlations and less error than simulations using a frictionless sliding at this contact surface. Strain rates over 100/s were observed in certain elements in the femoral neck and trochanter, indicating that additional research is required to better quantify the strain rate dependencies of both trabecular and cortical bone at these strain rates. These results represent the current benchmark in dynamic FE modeling of the proximal femur in sideways falls. Future work should also investigate improvements in experimental validation techniques by developing better displacement measurements and by enhancing the biofidelity of the impact loading wherever possible.
ISSN:1751-6161
1878-0180
1878-0180
DOI:10.1016/j.jmbbm.2017.10.033