Pull-off characterization of FRCM/Concrete interface
Fabric-reinforced cementitious matrix (FRCM) composites are usually surface-applied for strengthening reinforced concrete (RC) structures. The efficacy of the FRCM strengthening systems is dependent on the FRCM/concrete bond performance. This paper reports on the experimental results of FRCM/concret...
Gespeichert in:
Veröffentlicht in: | Composites. Part B, Engineering Engineering, 2019-05, Vol.165, p.545-553 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Fabric-reinforced cementitious matrix (FRCM) composites are usually surface-applied for strengthening reinforced concrete (RC) structures. The efficacy of the FRCM strengthening systems is dependent on the FRCM/concrete bond performance. This paper reports on the experimental results of FRCM/concrete bond characterization through pull-off tests. Six FRCM-strengthened RC slabs (500mm×500mm×100 mm) were prepared and enabled conducting 72 FRCM/concrete pull-off tests. The parameters investigated included: (a) FRCM material (carbon or polyparaphenylene benzobisoxazole (PBO)); (b) level of substrate roughness (no/low/high roughening); and (c) specimen's test age (7, 28, 56, and 84 days). All FRCM systems were single-plied. The study revealed a significance of the surface preparation and test age of specimens on the FRCM/concrete pull-off strength. High-roughness specimens showed an average of 74% pull-off strength increase compared to those without roughening. Also, specimens tested at Day 84 showed 54% strength increase compared to those tested at Day 7, on average. PBO-FRCM system showed slightly higher pull-off strength than that of the carbon counterpart. The specimens showed two distinctive failure types at the (i) fabric/mortar interface and (ii) concrete/matrix interface: the latter was more prominent in carbon-FRCM. Nonetheless, the failure mode was most dependent on the fabric geometry and the substrate roughness. Based on a statistical analysis of the tested specimens, prediction models were proposed for the FRCM/concrete pull-off strength and failure mode.
•Pull-off characterization was performed on FRCM/concrete bond.•Two FRCM fabrics were compared: carbon and PBO.•The level of surface roughening and the specimen's testing age were included as other parameters.•Pull-off strength increased with an increase in substrate roughness and testing age.•Two distinct failures were observed: debonding at concrete/matrix and fabric/matrix interfaces. |
---|---|
ISSN: | 1359-8368 1879-1069 1879-1069 |
DOI: | 10.1016/j.compositesb.2019.02.025 |