Greywater pollution variability and loadings

Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min −1. Co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ecological engineering 2009-05, Vol.35 (5), p.661-669
Hauptverfasser: Eriksson, Eva, Andersen, Henrik R., Madsen, Toke S., Ledin, Anna
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min −1. Concentrations of both macro- and micro-pollutants (organic matter and parabens) were found to range by several orders of magnitude in the influent, based on sampling every 20 min. Paraben degradation was proven to occur in the rotating biological contactor (RBC), while the remnant organic matter in the effluent was proved not to be readily degradable. Ammonium content, presumably from urine contamination, was found to undergo nitrification in the RBC. Mass flow (daily loads) for individual substances was calculated for several pollutants. Macropollutants were found to be generated in low numbers of grams per person per day, whereas the paraben loadings were below 1 mg per person per day. These data are highly relevant for comparing decentralised treatment options with existing end-of-pipe treatments, for feeding into risk assessments and for design purposes.
ISSN:0925-8574
1872-6992
1872-6992
DOI:10.1016/j.ecoleng.2008.10.015