Non-invasive investigations of potential renal artery stenosis in renal insufficiency

Background. The diagnostic value of non-invasive methods for diagnosing renal artery stenosis in patients with renal insufficiency is incompletely known. Methods. Forty-seven consecutive patients with moderately impaired renal function and a clinical suspicion of renal artery stenosis were investiga...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nephrology, dialysis, transplantation dialysis, transplantation, 2010-11, Vol.25 (11), p.3607-3614
Hauptverfasser: Eriksson, Per, Mohammed, Ahmed Abdulilah, De Geer, Jakob, Kihlberg, Johan, Persson, Anders, Granerus, Göran, Nyström, Fredrik, Smedby, Örjan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background. The diagnostic value of non-invasive methods for diagnosing renal artery stenosis in patients with renal insufficiency is incompletely known. Methods. Forty-seven consecutive patients with moderately impaired renal function and a clinical suspicion of renal artery stenosis were investigated with computed tomography angiography (CTA), gadolinium-enhanced magnetic resonance angiography (MRA), contrast-enhanced Doppler ultrasound and captopril renography. The primary reference standard was stenosis reducing the vessel diameter by at least 50% on CTA, and an alternative reference standard (‘morphological and functional stenosis’) was defined as at least 50% diameter reduction on CTA or MRA, combined with a positive finding from ultrasound or captopril renography. Results. The frequency of positive findings, calculated on the basis of individual patients, was 70% for CTA, 60% for MRA, 53% for ultrasound and 30% for captopril renography. Counting kidneys rather than patients, corresponding frequencies were 53%, 41%, 29% and 15%, respectively. In relation to the CTA standard, the sensitivity (and specificity) at the patient level was 0.81 (0.79) for MRA, 0.70 (0.89) for ultrasound and 0.42 (1.00) for captopril renography, and at the kidney level 0.76 (0.82), 0.53 (0.81) and 0.30 (0.86), respectively. Relative to the alternative reference standard, corresponding values at the patient level were 1.00 (0.62) for CTA, 0.90 (0.69) for MRA, 0.91 (1.00) for ultrasound and 0.67 (1.00) for captopril renography, and at the kidney level 0.96 (0.76), 0.85 (0.79), 0.71 (0.97) and 0.50 (0.97), respectively. Conclusions. CTA and MRA are superior to ultrasound and captopril renography at diagnosing morphological stenosis, but ultrasound may be useful as a screening method and captopril renography for verifying renin-dependent hypertension.
ISSN:0931-0509
1460-2385
1460-2385
DOI:10.1093/ndt/gfq259