Quantitative assessment and repeatability of chlorine in exhaled breath condensate : Comparison of two types of condensators

Background: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF. Objectives: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing tw...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiration 2005-01, Vol.72 (5), p.529-536
Hauptverfasser: DAVIDSSON, A, NAIDU SJÖSWÄRD, K, LUNDMAN, L, SCHMEKEL, B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF. Objectives: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing two separate condensators (Ecoscreen ® and R Tube ™ ) regarding recovery and repeatability. Furthermore, the association between condensate recoveries and variations in the airway status were scrutinized. Methods: EBC was collected using two condensators from 10 healthy volunteers. In addition, 13 asthmatic patients produced EBC with or without an added resistance of 5 cm H 2 O (Res5), applied to the outflow tract of Ecoscreen. All tests were done in random order. Chlorine levels (analyzed by a coulometric technique) in EBC served as a tool for investigation. Results: Chlorine was measurable in all samples. The coefficient of repeatability of chlorine measurements was <10%. Chlorine levels were higher in EBC obtained from R Tube (p < 0.001), and differences in recoveries and variability in chlorine levels were presumably related to technical differences in the condensators and not to the repeatability of chlorine measurements per se. Air-flow-dependent chlorine levels were obtained from healthy volunteers. Application of Res5, recruiting additional alveoli, resulted in increased recovery of the EBC volume, but not of chlorine, from those that had the most pronounced airway obstruction (p = 0.05). Conclusion: We conclude that by employing a sensitive analysis technique, chlorine is repeatedly measurable in EBC. We suggest that the bulk of chlorine in EBC originates from large airways and not from the alveolar area. Both condensators were comparable regarding repeatability but differed regarding chlorine recover
ISSN:0025-7931
1423-0356
1423-0356
DOI:10.1159/000087679