Fission matrix based Monte Carlo criticality calculations

We have described a fission matrix based method that allows to cancel the inactive cycles in Monte Carlo criticality calculations. The fission matrix must be sampled in the course of the Monte Carlo calculation using a space mesh with sufficiently small zones as it causes the fission matrix be insen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of nuclear energy 2009-08, Vol.36 (8), p.1270-1275
Hauptverfasser: Dufek, Jan, Gudowski, Wacław
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have described a fission matrix based method that allows to cancel the inactive cycles in Monte Carlo criticality calculations. The fission matrix must be sampled in the course of the Monte Carlo calculation using a space mesh with sufficiently small zones as it causes the fission matrix be insensitive to errors in the initial fission source. The k eff and other quantities can be derived by means of the final fission matrix. The confidence interval for the k eff estimate can be conservatively determined via the variance in the fission matrix.
ISSN:0306-4549
1873-2100
1873-2100
DOI:10.1016/j.anucene.2009.05.003