Highly selective and antifouling electrochemical biosensors for sensitive MicroRNA assaying based on conducting polymer polyaniline functionalized with zwitterionic peptide

Ultrasensitive and low-fouling microRNA electrochemical biosensors were successfully constructed by introducing thiol-terminated antifouling molecules (peptide sequence, polyethylene glycol, or mercapto alcohol) onto the surface of polyaniline-modified electrodes. For the three kinds of antifouling...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2021, Vol.413 (2), p.543-553
Hauptverfasser: Wang, Dongwei, Wang, Jiasheng, Song, Zhiling, Hui, Ni
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Ultrasensitive and low-fouling microRNA electrochemical biosensors were successfully constructed by introducing thiol-terminated antifouling molecules (peptide sequence, polyethylene glycol, or mercapto alcohol) onto the surface of polyaniline-modified electrodes. For the three kinds of antifouling materials investigated, the newly designed and synthesized peptide exhibited superior antifouling ability to others, and it could effectively reduce the nonspecific adsorption of proteins and even prevent the fouling effect of serum. Compared with microRNA biosensors without antifouling capability, or those modified with polyethylene glycol or mercapto alcohol, the biosensor modified with the designed zwitterionic peptide showed the highest specificity for single-base mismatch, three-base mismatch, and completely complementary microRNAs. Most interestingly, the experimental results indicated that the introduction of antifouling molecules to the sensing interfaces did not significantly change the sensitivity of the biosensor. The strategy of constructing antifouling biosensors based on newly synthesized zwitterionic peptides and conducting polymers can be promisingly extended to the development of other electrochemical sensors and biosensors without encountering biofouling. Graphical abstract Ultrasensitive and low-fouling microRNA electrochemical biosensors were constructed by introducing thiol-terminated antifouling molecules (peptide sequence, polyethylene glycol, or mercapto alcohol) onto the surface of polyaniline-modified electrodes. The biosensor modified with the designed zwitterionic peptide showed the highest specificity amongst four kinds of biosensors.
ISSN:1618-2642
1618-2650