Performance comparison of liquid, vapor, and liquid–vapor injection of single-screw compressor for an air-source heat pump
Refrigerant injection techniques are usually proposed to improve the performance and reliability of compressors when a single-screw compressor applied to an air-source heat pump works at low temperatures in winter. In this study, an experimental study was conducted to present the performance compari...
Gespeichert in:
Veröffentlicht in: | AIP advances 2024-05, Vol.14 (5), p.055319-055319-8 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Refrigerant injection techniques are usually proposed to improve the performance and reliability of compressors when a single-screw compressor applied to an air-source heat pump works at low temperatures in winter. In this study, an experimental study was conducted to present the performance comparison of the single-screw compressor in the air-source heat pump under liquid, vapor, and liquid–vapor refrigerant injection at evaporation temperatures between −19 and −8 °C. The results indicate that, when the evaporation temperature decreases from −8 to −19 °C, the heating capacity under liquid–vapor and vapor injection increases by 16.7% and 12.7%, respectively, compared with that under liquid injection and that the COPh increment under liquid–vapor injection and vapor injection is, respectively, from 11.23% to 39.21% and from 17.18% to 30.82% compared with that under liquid injection. Therefore, the liquid–vapor injection method is conducive to the operation of the air-source heat pump at a lower ambient temperature. The experimental results can provide the basis for the future design of single-screw compressors applied to air-source heat pumps. |
---|---|
ISSN: | 2158-3226 2158-3226 |
DOI: | 10.1063/5.0205332 |