Indoor environmental quality (IEQ) of school classrooms: Case study in Malaysia

Thermal Comfort is one of the key criteria for occupants’ comfort and productivity in a building. In schools, it is vital for a conduciveness for teaching and learning environment. Thermal comfort is dependent on air temperature, humidity, radiation, internal lighting, air movement, activities, clot...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Samad, Muna Hanim Abdul, Aziz, Zalena Abdul, Isa, Mohd Hafizal Mohd
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Thermal Comfort is one of the key criteria for occupants’ comfort and productivity in a building. In schools, it is vital for a conduciveness for teaching and learning environment. Thermal comfort is dependent on air temperature, humidity, radiation, internal lighting, air movement, activities, clothing and climatic change and is part of the Indoor Environmental Quality (IEQ) components which have has significant effects on occupants. The main concern over energy and running cost has meant that most public schools in Malaysia are designed for natural ventilation and not air-conditioning. The building envelope plays a significant role in reducing the radiant heat and keeps the interior cooler than the outdoor temperature for acceptable thermal comfort level. The requirement of Industrial Building System (IBS) as the envelope system for school building in Malaysia could affect the role of envelope as a climate moderator. This paper is based on a research conducted on two schools in Malaysia of varied construction materials as the building envelopes to ascertain the thermal comfort level of the classrooms. Elements of IEQ such as air temperature, air movement, daylighting and noise level were taken of various classrooms to fulfill the required objectives of determining the level of quality. The data collected and analysed from the study shows that in terms of air temperature which range from 28°C to 34.5°C, the schools do not achieve the recommended comfort level for tropical climate. As for daylighting element, results also show that some classrooms suffered with too much glare whilst others had insufficient daylighting. The findings also show the unsatisfactory level of air movement in the classrooms as well as an unacceptable noise level exceeding the allowable threshold. This research also concluded that the use of materials and orientation in the school design are the major determinant factors towards good IEQ levels in school buildings.
ISSN:0094-243X
1551-7616
DOI:10.1063/1.5005784