Multi-second neutral beam injector (60kV, 6A) for plasma diagnostics in the upgraded T-15 device
A diagnostic neutral beam injector DINA-KI60 has been developed and produced for upgraded T-15 tokamak (Kurchatov Institute, Moscow). The system will be primarily used for measurement of the ion temperature by charge-exchange recombination spectroscopy (CXRS), for magnetic field measurements via mot...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A diagnostic
neutral beam
injector DINA-KI60 has been developed and produced for upgraded T-15 tokamak (Kurchatov Institute,
Moscow). The system will be primarily used for measurement of the ion temperature by charge-exchange recombination
spectroscopy (CXRS), for magnetic field measurements via motional Stark
effect (MSE) and investigation of plasma turbulence by Beam
emission
spectroscopy (BES). The ion source provides 60 keV, 6 A hydrogen
beam with low
angular divergence less than 10 mrad. Ions are extracted from a plasma created by an
arc-discharge source with cold cathode and, after accelerating and focusing, are
neutralized in a gas target. The extracted beam has about 86% of full energy specie. The grids of ion
optical system are spherically curved providing geometric focusing of the beam at a distance 4 m.
Diagnostic
neutral beam has
been successfully tested at Budker Institute of Nuclear Physics at 2 seconds pulse
duration with modulation of the beam (duty ratio from 1:1 to 1:3). |
---|---|
ISSN: | 0094-243X 1551-7616 |
DOI: | 10.1063/1.4964206 |