ECE diagnostic for the TARA tandem mirror machine using a fast‐scanning Michelson interferometer
This ECE (electron cyclotron emission) diagnostic utilizes a fast‐scanning Michelson interferometer to determine two parameters, the temperature and the loss cone angle, of the distribution function of the hot electrons (T≳100 keV) generated in the axisymmetric plug plasma of the TARA tandem mirror...
Gespeichert in:
Veröffentlicht in: | Rev. Sci. Instrum.; (United States) 1986-08, Vol.57 (8), p.1965-1967 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This ECE (electron cyclotron emission) diagnostic utilizes a fast‐scanning Michelson interferometer to determine two parameters, the temperature and the loss cone angle, of the distribution function of the hot electrons (T≳100 keV) generated in the axisymmetric plug plasma of the TARA tandem mirror device. The radiation transport system employs a lens relay and a low‐pass grating filter in order to transmit the synchrotron radiation over a spectral range of 2.9–18.6 cm−
1. This enables us to study the emitted radiation spectrum up to the 40th harmonic of the electron–cyclotron frequency in the plug plasma (B=5 kG). Details of the design principles and the development of the diagnostic at TARA will be presented. |
---|---|
ISSN: | 0034-6748 1089-7623 |
DOI: | 10.1063/1.1138808 |