Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis

To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arquivos brasileiros de oftalmologia 2017-06, Vol.80 (3), p.172-175
Hauptverfasser: Machado, Marco Antonio de Campos, Silva, João Amaro Ferrari, Garcia, Eduardo Alonso, Allemann, Norma
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p
ISSN:0004-2749
1678-2925
1678-2925
DOI:10.5935/0004-2749.20170042