Sirolimus-Eluting versus Bare-Metal Low-Profile Stent for Renal Artery Treatment (GREAT Trial): Angiographic Follow-up after 6 Months and Clinical Outcome up to 2 Years

Purpose: To evaluate the patency of sirolimus-eluting stents (SES) compared to bare-metal stents (BMS) in the treatment of atherosclerotic renal artery stenosis (RAS). Methods: Between November 2001 to June 2003, 105 consecutive symptomatic patients (53 men; mean age 65.7 years) with RAS were treate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endovascular therapy 2007-08, Vol.14 (4), p.460-468
Hauptverfasser: Zähringer, Markus, Sapoval, Marc, Pattynama, Peter M. T., Rabbia, Claudio, Vignali, Claudio, Maleux, Geert, Boyer, Louis, Szczerbo-Trojanowska, Malgorzata, Jaschke, Werner, Hafsahl, Geir, Downes, Mark, Bérégi, Jean-Paul, Veeger, Nic J. G. M., Stoll, Hans-Peter, Talen, Aly
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To evaluate the patency of sirolimus-eluting stents (SES) compared to bare-metal stents (BMS) in the treatment of atherosclerotic renal artery stenosis (RAS). Methods: Between November 2001 to June 2003, 105 consecutive symptomatic patients (53 men; mean age 65.7 years) with RAS were treated with either a bare-metal (n=52) or a drug-eluting (n=53) low-profile Palmaz-Genesis peripheral stent at 11 centers in a prospective nonrandomized trial. The primary endpoint was the angiographic result at 6 months measured with quantitative vessel analysis by an independent core laboratory. Secondary endpoints were technical and procedural success, clinical patency [no target lesion revascularization (TLR)], blood pressure and antihypertensive drug use, worsening of renal function, and no major adverse events at 1, 6, 12, and 24 months. Results: At 6 months, the overall in-stent diameter stenosis for BMS was 23.9%±22.9% versus 18.7%±15.6% for SES (p=0.39). The binary restenosis rate was 6.7% for SES versus 14.6% for the BMS (p=0.30). After 6 months and 1 year, TLR rate was 7.7% and 11.5%, respectively, in the BMS group versus 1.9% at both time points in the SES group (p=0.21). This rate remained stable up to the 2-year follow-up but did not reach significance due to the small sample. Even as early as 6 months, both types of stents significantly improved blood pressure and reduced antihypertensive medication compared to baseline (p
ISSN:1526-6028
1545-1550
DOI:10.1177/152660280701400405