Ultramicro and ultrasensitive detection of lipopolysaccharides based on triple-signal amplification ultrafast ATRP and an ultramicroelectrode

Highly sensitive testing of trace lipopolysaccharides (LPS) is very important due to their high toxicity to the human body. Here, an ultrasensitive electrochemical sensor requiring only 5 μL solution was developed for LPS detection via triple-signal amplification based on ultrafast atom transfer rad...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2023-12, Vol.148 (24), p.6359-6368
Hauptverfasser: Jiang, Shipeng, Sun, Mingyang, Meng, Peiran, Zhang, Xiaoyu, Sun, Yue
Format: Artikel
Sprache:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Highly sensitive testing of trace lipopolysaccharides (LPS) is very important due to their high toxicity to the human body. Here, an ultrasensitive electrochemical sensor requiring only 5 μL solution was developed for LPS detection via triple-signal amplification based on ultrafast atom transfer radical polymerization (UATRP) and a Au ultramicroelectrode (UME). Firstly, the Au UME was modified with gold nanoparticles (nAu) and an LPS aptamer (Apt) in turn. When the Apt recognized LPS, the ATRP initiator of 4-(bromomethyl)phenylboronic acid (BPA) could be tethered to the electrode by covalent cross-linking between the phenylboronic acid moiety and the cis -diol site of LPS. Then UATRP was conducted for 2.5 min with nitrogen-doped carbon quantum dots (N-CQDs) as the photocatalyst and methylacrolein (MLA) as the monomer. After the electroactive probes of Ag nanoparticles (AgNPs) were formed on the surface of poly(MLA) by the silver mirror reaction, the electrochemical sensor was successfully prepared. Under the optimal conditions, the sensor exhibited a lower detection limit and a wider linear range when it was compared with a similar assay for LPS. In particular, the LOD of 7.99 × 10 −2 pg mL −1 was better than that of the limulus amoebocyte lysate (LAL)-based technique, which is the gold standard for LPS detection. In the end, the sensor reported in this paper showed good selectivity and satisfactory feasibility for LPS detection in real biological samples and food products. The results obtained from the drug, blood and potable water samples laid a strong foundation for its clinical applications and application in other fields. An ultrasensitive electrochemical sensor requiring 5 μL solution was developed for lipopolysaccharide detection via triple-signal amplification based on UATRP.
ISSN:0003-2654
1364-5528