Using single-particle ICP-MS for monitoring metal-containing particles in tap waterElectronic supplementary information (ESI) available: As figures, (i) comparison of metal-containing particles between the AM and PM samples and (ii) the instrumental set-up for spICP-MS of tap water samples. See DOI: 10.1039/c8ew00478a

Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems ( e.g. , corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples ( n = 50) collected from three buildings t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Venkatesan, Arjun K, Rodríguez, Blanca T, Marcotte, Aurelie R, Bi, Xiangyu, Schoepf, Jared, Ranville, James F, Herckes, Pierre, Westerhoff, Paul
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems ( e.g. , corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples ( n = 50) collected from three buildings to analyze for Pb, Fe, Sn, Cu, Ag and Ti-containing particles. The Pb, Sn and Fe-containing particles were detected at an average concentration (ng L −1 ) of 1.2 (range: 0.06-4.8), 1.8 (range: 0.11-14), and 88 (range: 26-890), respectively, representing the corresponding total dissolved metal concentrations at a minimum of 0.4%, 10%, and 15%. No particulate Ti and Ag were observed in the samples. The Pb concentrations in the first 125 mL fraction collected were on average three times higher than those in the subsequent samples. Detection of the Cu particles required modification of the sample introduction system (direct self-aspiration into the nebulizer) to reduce matrix interaction with the auto-sampler tubing. The Cu particles were detected in 50% of the analyzed samples at an average concentration of 69 (range: 15-136) ng L −1 . While all the metal concentrations were below the health advisory levels, this study showcases the feasibility and first application of spICP-MS to monitor metal-containing particles in tap waters, and the results suggest that the particulate forms of the studied elements may represent a significant fraction of the bulk elemental concentration in tap water. This study provides the feasibility of using a single-particle ICP-MS technique for convenient and routine monitoring of engineered nanomaterials in tap water.
ISSN:2053-1400
2053-1419
DOI:10.1039/c8ew00478a