High-throughput assessment of catalyst stability during autothermal reforming of model biogas

The long-term stability of Ni-based catalysts for autothermal reforming of model biogas has been assessed in a six parallel-flow reactor set-up implemented to test simultaneously six different catalysts at 700 °C under a feed consisting of 42% H 2 O, 14% CH 4 , 9% CO 2 , and 7% O 2 in argon. The rep...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catalysis science & technology 2015-01, Vol.5 (9), p.439-4397
Hauptverfasser: Luneau, M, Schuurman, Y, Meunier, F. C, Mirodatos, C, Guilhaume, N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The long-term stability of Ni-based catalysts for autothermal reforming of model biogas has been assessed in a six parallel-flow reactor set-up implemented to test simultaneously six different catalysts at 700 °C under a feed consisting of 42% H 2 O, 14% CH 4 , 9% CO 2 , and 7% O 2 in argon. The reproducibility of catalyst performance measured in the 6 parallel reactors was ascertained using a commercial Ni-based catalyst. A screening of 12 catalyst formulations identified 5-0.05 wt% Ni-Rh/MgAl 2 O 4 as a robust catalyst for autothermal reforming of model biogas over 200 h time-on-stream. A six parallel-flow reactor set-up was implemented to assess the long-term stability of Ni-based catalysts for autothermal reforming of model biogas.
ISSN:2044-4753
2044-4761
DOI:10.1039/c5cy00702j