Improvement of the gas cluster ion beam-(GCIB)-based molecular secondary ion mass spectroscopy (SIMS) depth profile with O cosputtering

Over the last decade, cluster ion beams have displayed their capability to analyze organic materials and biological specimens. Compared with atomic ion beams, cluster ion beams non-linearly enhance the sputter yield, suppress damage accumulation and generate high mass fragments during sputtering. Th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2016-04, Vol.141 (8), p.2523-2533
Hauptverfasser: Chu, Yi-Hsuan, Liao, Hua-Yang, Lin, Kang-Yi, Chang, Hsun-Yun, Kao, Wei-Lun, Kuo, Ding-Yuan, You, Yun-Wen, Chu, Kuo-Jui, Wu, Chen-Yi, Shyue, Jing-Jong
Format: Artikel
Sprache:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Over the last decade, cluster ion beams have displayed their capability to analyze organic materials and biological specimens. Compared with atomic ion beams, cluster ion beams non-linearly enhance the sputter yield, suppress damage accumulation and generate high mass fragments during sputtering. These properties allow successful Secondary Ion Mass Spectroscopy (SIMS) analysis of soft materials beyond the static limit. Because the intensity of high mass molecular ions is intrinsically low, enhancing the intensity of these secondary ions while preserving the sample in its original state is the key to highly sensitive molecular depth profiles. In this work, bulk poly(ethylene terephthalate) (PET) was used as a model material and analyzed using Time-of-Flight SIMS (ToF-SIMS) with a pulsed Bi 3 2+ primary ion. The optimized hardware of a 10 kV Ar 2500 + Gas Cluster Ion Beam (GCIB) with a low kinetic energy (200500 V) oxygen ion (O 2 + ) as a cosputter beam was employed for generating depth profiles and for examining the effect of beam parameters. The results were then quantitatively analyzed using an established erosion model. It was found that the ion intensity of the PET monomer ([M + H] + ) and its large molecular fragment ([M C 2 H 4 O + H] + ) steadily declined during single GCIB sputtering, with distortion of the distribution information. However, under an optimized GCIB-O 2 + cosputter, the secondary ion intensity quickly reached a steady state and retained >95% intensity with respect to the pristine surface, although the damage cross-section was larger than that of single GCIB sputtering. This improvement was due to the oxidation of molecules and the formation of OH groups that serve as proton donors to particles emitted from the surface. As a result, the ionization yield was enhanced and damage to the chemical structure was masked. Although O 2 + is known to alter the chemical structure and cause damage accumulation, the concurrently used GCIB could sufficiently remove the surface layer and allow the damage to be masked by the enhanced ionization yield when the ion-solid interaction volume was kept shallow with a low O 2 + energy. This low O 2 + energy (200 V) cosputtering also produced a smoother surface than a single GCIB. Because the oxidized species were produced by O 2 + and removed by GCIB simultaneously, a sufficiently high O 2 + current density was required to produce adequate enhancements. Therefore, it was found that 10 kV with 2 10 6 A per
ISSN:0003-2654
1364-5528
DOI:10.1039/c5an02677f