Mortality analysis of endovascular aneurysm sealing versus endovascular aneurysm repair
Endovascular aneurysm sealing (EVAS), using the Nellix endovascular aneurysm sealing system, has been associated with high reintervention and migration rates. However, prior reports have suggested that EVAS might be related to a lower all-cause mortality compared with endovascular aneurysm repair (E...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery 2023-03, Vol.77 (3), p.731-740.e1 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Endovascular aneurysm sealing (EVAS), using the Nellix endovascular aneurysm sealing system, has been associated with high reintervention and migration rates. However, prior reports have suggested that EVAS might be related to a lower all-cause mortality compared with endovascular aneurysm repair (EVAR). In the present study, we examined the 5-year all-cause mortality trends after EVAS and EVAR.
We compared the 333 EVAS patients in the EVAS-1 Nellix U.S. investigational device exemption trial with 16,497 infrarenal EVAR controls from the Vascular Quality Initiative, treated between 2014 and 2016, after applying the exclusion criteria from the investigational device exemption trial (ie, hemodialysis, creatinine >2.0 mg/dL, rupture). As a secondary analysis, we stratified the patients by aneurysm diameter ( |
---|---|
ISSN: | 0741-5214 1097-6809 |
DOI: | 10.1016/j.jvs.2022.10.030 |