Diagnostic Accuracy of a Convolutional Neural Network Assessment of Solitary Pulmonary Nodules Compared With PET With CT Imaging and Dynamic Contrast-Enhanced CT Imaging Using Unenhanced and Contrast-Enhanced CT Imaging

Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy. What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compare...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chest 2023-02, Vol.163 (2), p.444-454
Hauptverfasser: Weir-McCall, Jonathan R., Debruyn, Elise, Harris, Scott, Qureshi, Nagmi R., Rintoul, Robert C., Gleeson, Fergus V., Gilbert, Fiona J., Lucy Brindle, Anindo Banerjee, Callister, Matthew, Clegg, Andrew, Cook, Andrew, Cozens, Kelly, Crosbie, Philip, Dizdarevic, Sabina, Eaton, Rosemary, Eichhorst, Kathrin, Frew, Anthony, Groves, Ashley, Han, Sai, Jones, Jeremy, Kankam, Osie, Karunasaagarar, Kavitasagary, Kurban, Lutfi, Little, Louisa, Madden, Jackie, McClement, Chris, Miles, Ken, Moate, Patricia, Peebles, Charles, Pike, Lucy, Poon, Fat-Wui, Sinclair, Donald, Shah, Andrew, Vale, Luke, George, Steve, Riley, Richard, Lodge, Andrea, Buscombe, John, Green, Theresa, Stone, Amanda, Navani, Neal, Shortman, Robert, Azzopardi, Gabriella, Doffman, Sarah, Bush, Janice, Lyttle, Jane, Jacob, Kenneth, Horst, Joris van der, Sarvesvaran, Joseph, McLaren, Barbara, Gomersall, Lesley, Sharma, Ravi, Collie, Kathleen, O’Hickey, Steve, Tyler, Jayne, King, Sue, O’Brien, John, Srivastava, Rajiv, Lloyd-Jones, Hugh, Beech, Sandra, Scarsbrook, Andrew, Ashford-Turner, Victoria, Smith, Elaine, Mbale, Susan, Adams, Nick, Pottinger, Gail
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy. What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup? This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules trial, a prospective multicenter study comparing the diagnostic accuracy of dynamic contrast-enhanced (DCE) CT imaging with PET imaging in SPNs. The LCP-CNN was designed and validated in an external cohort. LCP-CNN-generated risk scores were created from the noncontrast and contrast-enhanced CT scan images from the DCE CT imaging. The gold standard was histologic analysis or 2 years of follow-up. The area under the receiver operating characteristic curves (AUC) were calculated using LCP-CNN score, maximum standardized uptake value, and DCE CT scan maximum enhancement and were compared using the DeLong test. Two hundred seventy participants (mean ± SD age, 68.3 ± 8.8 years; 49% women) underwent PET with CT scan imaging and DCE CT imaging with CT scan data available centrally for LCP-CNN analysis. The accuracy of the LCP-CNN on the noncontrast images (AUC, 0.83; 95% CI, 0.79-0.88) was superior to that of DCE CT imaging (AUC, 0.76; 95% CI, 0.69-0.82; P = .03) and equal to that of PET with CT scan imaging (AUC, 0.86; 95% CI, 0.81-0.90; P = .35). The presence of contrast resulted in a small reduction in diagnostic accuracy, with the AUC falling from 0.83 (95% CI, 0.79-0.88) on the noncontrast images to 0.80 to 0.83 after contrast (P < .05 for 240 s after contrast only). An LCP-CNN algorithm provides an AUC equivalent to PET with CT scan imaging in the diagnosis of solitary pulmonary nodules. ClinicalTrials.gov Identifier; No.: NCT02013063
ISSN:0012-3692
1931-3543
DOI:10.1016/j.chest.2022.08.2227