Apnoeic oxygenation in morbid obesity: a randomised controlled trial comparing facemask and high-flow nasal oxygen delivery
Obesity is a risk factor for airway-related incidents during anaesthesia. High-flow nasal oxygen has been advocated to improve safety in high-risk groups, but its effectiveness in the obese population is uncertain. This study compared the effect of high-flow nasal oxygen and low-flow facemask oxygen...
Gespeichert in:
Veröffentlicht in: | British journal of anaesthesia : BJA 2023-01, Vol.130 (1), p.103-110 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Obesity is a risk factor for airway-related incidents during anaesthesia. High-flow nasal oxygen has been advocated to improve safety in high-risk groups, but its effectiveness in the obese population is uncertain. This study compared the effect of high-flow nasal oxygen and low-flow facemask oxygen delivery on duration of apnoea in morbidly obese patients.
Morbidly obese patients undergoing bariatric surgery were randomly allocated to receive either high-flow nasal (70 L min−1) or facemask (15 L min−1) oxygen. After induction of anaesthesia, the patients were apnoeic for 18 min or until peripheral oxygen saturation decreased to 92%.
Eighty patients were studied (41 High-Flow Nasal Oxygen, 39 Facemask). The median apnoea time was 18 min in both the High-Flow Nasal Oxygen (IQR 18–18 min) and the Facemask (inter-quartile range [IQR], 4.1–18 min) groups. Five patients in the High-Flow Nasal Oxygen group and 14 patients in the Facemask group desaturated to 92% within 18 min. The risk of desaturation was significantly lower in the High-Flow Nasal Oxygen group (hazard ratio=0.27; 95% confidence interval [CI], 0.11–0.65; P=0.007).
In experienced hands, apnoeic oxygenation is possible in morbidly obese patients, and oxygen desaturation did not occur for 18 min in the majority of patients, whether oxygen delivery was high-flow nasal or low-flow facemask. High-flow nasal oxygen may reduce desaturation risk compared with facemask oxygen. Desaturation risk is a more clinically relevant outcome than duration of apnoea. Individual physiological factors are likely to be the primary determinant of risk rather than method of oxygen delivery.
NCT03428256. |
---|---|
ISSN: | 0007-0912 1471-6771 |
DOI: | 10.1016/j.bja.2021.12.011 |