Case report: peri-device leakage after percutaneous left atrial appendage occlusion: plug, clip, or amputate?

Abstract Background Although peri-device leakage is frequently observed after left atrial appendage occlusion (LAAO), there is no consensus on the optimal management strategy. It is unknown whether additional plugging should be preferred over surgical exclusion of the LAA, as experience with additio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal : case reports 2023-01, Vol.7 (1), p.ytac494
Hauptverfasser: Ramdat Misier, Nawin L, Kharbanda, Rohit K, van Schaagen, Frank R N, de Groot, Natasja M S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Although peri-device leakage is frequently observed after left atrial appendage occlusion (LAAO), there is no consensus on the optimal management strategy. It is unknown whether additional plugging should be preferred over surgical exclusion of the LAA, as experience with additional plugging is limited. Case summary In this case report, we demonstrate the clinical implications of additional plugging and surgical exclusion in a 65-year-old male patient with peri-device leakage and recurrent thromboembolic events. After the recurrence of paroxysmal atrial fibrillation (AF) and a transient ischaemic attack despite adequate anticoagulation, the patient was opted for re-do pulmonary vein isolation and LAAO with a Watchman device. Due to multiple ischaemic strokes and recurrent AF in combination with significant peri-device leakage, additional plugging with a second device was performed. Post-procedurally, the patient had another ischaemic stroke and persisting peri-device leakage was observed during follow-up. Due to progressive symptoms of AF and patient’s preference to discontinue DOAC, he underwent a Cox MAZE IV procedure, including amputation of the LAA with both devices. Within six months after surgery, the patient experienced two more ischaemic events. In the following two years, the patient remained free of any cerebrovascular accidents or recurrence of AF. Discussion Additional plugging of peri-device leakage is not always successful in stroke prevention. In combination with recurrent AF, progressive symptoms, contraindication for oral anticoagulation, and patient’s preference, surgical LAA exclusion could be preferred over additional plugging.
ISSN:2514-2119
2514-2119
DOI:10.1093/ehjcr/ytac494