Validation of Pharyngeal Acid Reflux Episodes Using Hypopharyngeal Multichannel Intraluminal Impedance-pH
Hypopharyngeal multichannel intraluminal impedance-pH (HMII-pH) technology incorporating 2 trans-upper esophageal sphincter impedance channels has been developed to detect pharyngeal reflux. We used the HMII-pH technique to validate the candidate pharyngeal acid reflux (PAR) episodes based on the du...
Gespeichert in:
Veröffentlicht in: | Journal of neurogastroenterology and motility 2023-01, Vol.29 (1), p.49-57 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Hypopharyngeal multichannel intraluminal impedance-pH (HMII-pH) technology incorporating 2 trans-upper esophageal sphincter impedance channels has been developed to detect pharyngeal reflux. We used the HMII-pH technique to validate the candidate pharyngeal acid reflux (PAR) episodes based on the dual-pH tracings and determined the interobserver reproducibility.
We conducted a cross-sectional study in tertiary centers in Taiwan. Ninety patients with suspected laryngopharyngeal reflux and 28 healthy volunteers underwent HMII-pH test when off acid suppressants. Candidate PAR episodes were characterized by pharyngeal pH drops of at least 2 units and reaching a nadir pH of 5 within 30 seconds during esophageal acidification. Two experts manually independently identified candidate PAR episodes based on the dual-pH tracings. By reviewing the HMII-pH tracings, HMII-pH-proven PAR episodes were subsequently confirmed. The consensus reviews of HMII-pH-proven PAR episodes were considered to be the reference standard diagnosis. The interobserver reproducibility was assessed.
A total of 105 candidate PAR episodes were identified. Among them 84 (80.0%; 95% CI, 71.0-87.0%) were HMII-pH-proven PAR episodes (82 in 16 patients and 2 in 1 healthy subject). Patients tended to have more HMII-pH-proven PAR episodes than healthy controls (median and percentile values [25th, 75th, and 95th percentiles]: 0 [0, 0, 3] vs 0 [0, 0, 0],
= 0.067). The concordance rate in diagnosing HMII-pH-proven PAR episodes between 2 independent observers was 92.2%.
Our preliminary data showed that 80.0% (71.0-87.0%) of the proposed candidate PAR episodes were HMII-pH-proven PAR episodes, among which the interobserver reproducibility was good. |
---|---|
ISSN: | 2093-0879 2093-0887 |
DOI: | 10.5056/jnm22047 |