Multicenter Evaluation of the Cepheid Xpert GBS LB XC Test

Early-onset neonatal sepsis due to Streptococcus agalactiae (group B Streptococcus [GBS]) infection is one of the leading causes of newborn mortality and morbidity. The latest guidelines published in 2019 recommended universal screening of GBS colonization among all pregnant women and intrapartum an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical microbiology 2022-12, Vol.60 (12), p.e0135622-e0135622
Hauptverfasser: Thwe, Phyu M, Faron, Matthew L, Pride, David T, Cruz, Amorina, Gerstbrein, Derek, Nahmod, Karen A, Bigham, Lindsay, Du, Xiaotang, Lu, Xixi, Moya, Stephanie, Ren, Ping
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Early-onset neonatal sepsis due to Streptococcus agalactiae (group B Streptococcus [GBS]) infection is one of the leading causes of newborn mortality and morbidity. The latest guidelines published in 2019 recommended universal screening of GBS colonization among all pregnant women and intrapartum antibiotic prophylaxis for positive GBS. The updated procedures allow rapid molecular-based GBS screening using nutrient broth-enriched rectovaginal samples. Commercially available molecular assays for GBS diagnosis target mainly the gene, which encodes a hemolysin protein responsible for producing the Christie-Atkins-Munch-Petersen (CAMP) factor. is considered a conserved gene in essentially all GBS isolates. However, false-negative GBS results on Cepheid Xpert GBS and GBS LB tests due to deletions in or near the region that encodes were reported recently. Therefore, the new Xpert GBS LB XC test was developed. This study is a multicenter evaluation of the new test for GBS identification from nutrient broth-enriched rectal/vaginal samples from antepartum women. A total of 621 samples were prospectively enrolled. The samples were tested with the Xpert GBS LB XC test, the composite comparator method, which included the Hologic Panther Fusion GBS test combined with bacterial culture, followed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, and bacterial culture alone, followed by MALDI-TOF MS identification. The respective sensitivity and specificity of the Xpert GBS LB XC test were 99.3% and 98.7% compared to the composite comparator method and 99.1% and 91.8% compared to bacterial culture alone with MALDI-TOF MS identification. Overall, the Xpert GBS LB XC test performed comparatively to the composite comparator method and is equivalent to traditional bacterial culture followed by MALDI-TOF MS.
ISSN:0095-1137
1098-660X
DOI:10.1128/jcm.01356-22