Tidal volume expandability affected by flow, dynamic hyperinflation, and quasi-fixed inspiratory time in patients with COPD and healthy individuals

Exertional dyspnea (ED) and impaired exercise performance (EP) are mainly caused by dynamic hyperinflation (DH) in chronic obstructive pulmonary disease (COPD) patients by constraining tidal volume expansion at peak exercise (VTpeak). As VTpeak is the product of inspiratory time (TIpeak) and flow (V...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chronic respiratory disease 2022-10, Vol.19, p.14799731221133390-14799731221133390
1. Verfasser: Chuang, Ming-Lung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Exertional dyspnea (ED) and impaired exercise performance (EP) are mainly caused by dynamic hyperinflation (DH) in chronic obstructive pulmonary disease (COPD) patients by constraining tidal volume expansion at peak exercise (VTpeak). As VTpeak is the product of inspiratory time (TIpeak) and flow (VT/TIpeak), it was hypothesized that VTpeak and VTpeak/total lung capacity (VTpeak/TLC) may be affected by TIpeak and VT/TIpeak. Hence, the study investigated the (1) effect of TIpeak and VT/TIpeak on VTpeak expansion, (2) factors associated with TIpeak, expiratory time (TEpeak), VT/TIpeak, and VTpeak/TLC, and (3) relationships between VT/TIpeak and VTpeak/TLC with ED and EP in COPD patients and controls. The study enrolled 126 male stable COPD patients and 33 sex-matched controls. At peak exercise, TIpeak was similar in all subjects (COPD versus controls, mean ± SD: 0.78 ± 0.17 s versus 0.81 ± 0.20 s, p = NS), whereas the COPD group had lower VT/TIpeak (1.71 ± 0.49 L/s versus 2.58 ± 0.69 L/s, p < .0001) and thus the COPD group had smaller VTpeak (1.31 ± 0.34 L versus 2.01 ± 0.45 L,p < .0001) and VTpeak/TLC (0.22 ± 0.06 vs 0.33 ± 0.05, p < .0001). TIpeak, TEpeak, and VT/TIpeak were mainly affected by exercise effort, whereas VTpeak/TLC was not. TEpeak, VT/TIpeak, and VTpeak/TLC were inversely changed by impaired lung function. TIpeak was not affected by lung function. Dynamic hyperinflation did not occur in the controls, however, VTpeak/TLC was strongly inversely related to DH (r = −0.79) and moderately to strongly related to lung function, ED, and EP in the COPD group. There was a slightly stronger correlation between VTpeak/TLC with ED and EP than VT/TIpeak in the COPD group (|r| = 0.55–0.56 vs 0.38–0.43). In summary, TIpeak was similar in both groups and the key to understanding how flow affects lung expansion. However, the DH volume effect was more important than the flow effect on ED and EP in the COPD group.
ISSN:1479-9731
1479-9723
1479-9731
DOI:10.1177/14799731221133390