Wearable sensors for prediction of intraamniotic infection in women with preterm premature rupture of membranes: a prospective proof of principle study
Purpose To evaluate the use of wearable sensors for prediction of intraamniotic infection in pregnant women with PPROM. Materials and methods In a prospective proof of principle study, we included 50 patients diagnosed with PPROM at the University Hospital Zurich between November 2017 and May 2020....
Gespeichert in:
Veröffentlicht in: | Archives of gynecology and obstetrics 2023-11, Vol.308 (5), p.1447-1456 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
To evaluate the use of wearable sensors for prediction of intraamniotic infection in pregnant women with PPROM.
Materials and methods
In a prospective proof of principle study, we included 50 patients diagnosed with PPROM at the University Hospital Zurich between November 2017 and May 2020. Patients were instructed to wear a bracelet during the night, which measures physiological parameters including wrist skin temperature, heart rate, heart rate variability, and breathing rate. A two-way repeated measures ANOVA was performed to evaluate the difference over time of both the wearable device measured parameters and standard clinical monitoring values, such as body temperature, pulse, leucocytes, and C-reactive protein, between women with and without intraamniotic infection.
Results
Altogether, 23 patients (46%) were diagnosed with intraamniotic infection. Regarding the physiological parameters measured with the bracelet, we observed a significant difference in breathing rate (19 vs 16 per min,
P
|
---|---|
ISSN: | 1432-0711 0932-0067 1432-0711 |
DOI: | 10.1007/s00404-022-06753-4 |