Viral load may impact the diagnostic performance of nasal swabs in nucleic acid amplification test and quantitative antigen test for SARS-CoV-2 detection

Compared to nasopharyngeal swabs (NPS), there has been insufficient evaluation of the diagnostic performance of nasal swabs (NS) for the detection of severe acute respiratory coronavirus 2 (SARS-CoV-2) in the nucleic acid amplification test (NAAT) and quantitative SARS-CoV-2 antigen test (QAT). We p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy 2022-11, Vol.28 (11), p.1590-1593
Hauptverfasser: Fujiya, Yoshihiro, Sato, Yuki, Katayama, Yuki, Nirasawa, Shinya, Moriai, Mikako, Saeki, Masachika, Yakuwa, Yuki, Kitayama, Ikumi, Asanuma, Koichi, Kuronuma, Koji, Takahashi, Satoshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Compared to nasopharyngeal swabs (NPS), there has been insufficient evaluation of the diagnostic performance of nasal swabs (NS) for the detection of severe acute respiratory coronavirus 2 (SARS-CoV-2) in the nucleic acid amplification test (NAAT) and quantitative SARS-CoV-2 antigen test (QAT). We prospectively compared healthcare worker-collected and flocked NS within nine days after symptom onset to paired NPS to detect SARS-CoV-2 in NAAT and QAT on the fully automated Lumipulse system. The agreement between sample types was evaluated, and cycle threshold (Ct) values and antigen levels were used as surrogate viral load measures. Sixty sets of NPS and NS samples were collected from 40 patients with COVID-19. The overall agreements between NAAT and QAT samples were 76.7% and 65.0%, respectively. In NAAT, the Ct value of NS was significantly higher, 5.9, than that of NPS. Thirty-nine (95.1%) NS tested positive in 41 positive-paired NPS with Ct ≤ 30. The negative correlation was observed between antigen levels of NS in QAT and Ct values of NS in NAAT (r = −0.88). In QAT, the antigen level of NS was significantly lower than that of NPS. Thirty-six (90.0%) NS tested positive in 40 positive-paired NPS with antigen levels >100 pg/mL, which were collected significantly earlier than those with antigen levels ≤100 pg/mL. In NAAT and QAT, NS had limited performance in detecting SARS-CoV-2 compared to NPS. However, NS may be helpful for patients with COVID-19 with high viral loads or those in the early stages of the illness.
ISSN:1341-321X
1437-7780
DOI:10.1016/j.jiac.2022.07.023