Microparticle Manipulation Based on the Bulk Acoustic Wave Combined with the Liquid Crystal Backflow Effect Driving in 2D/3D Platforms
Microparticle manipulation has been widely used in clinical diagnosis, cell separation, and biochemical analysis via optics, electronics, magnetics, or acoustic wave driving. Among them, the bulk acoustic wave (BAW) driving method has been increasingly adopted because of non-contact, easy control, a...
Gespeichert in:
Veröffentlicht in: | ACS omega 2022-07, Vol.7 (29), p.25140-25151 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Microparticle manipulation has been widely used in clinical diagnosis, cell separation, and biochemical analysis via optics, electronics, magnetics, or acoustic wave driving. Among them, the bulk acoustic wave (BAW) driving method has been increasingly adopted because of non-contact, easy control, and precise manipulation. However, its low manipulation efficiency limits the usage of the BAW driving in high viscosity solutions. Therefore, in order to obtain larger driving force and more flexible manipulation of microparticles, both two-dimensional (2D) and three-dimensional (3D) platforms based on the BAW and liquid crystal backflow effect (LCBE) driving in liquid crystal (LC) solutions are proposed. The driving forces applied on the microparticles allow for the change of microparticle moving direction, which is also ascertained through theory analysis combined with various driving methods. Specifically, the maximum moving speed (68.78 μm/s) of the polystyrene particles is obtained by the BAW (13 Vpp) combined with LCBE (30 V) at a low frequency of 7.2 kHz in the 2D platform. Precise position manipulation in 3D is also fulfilled through a programmable logic control model using polystyrene particles as a demonstration. In addition, red blood cells mixed with LC solutions are arranged in a line or gathered in the pressure nodes of the BAW forces along with sinusoid signals generated by various transducer combinations. Therefore, it is approved that the LC solution that induces the LCBE force could increase the microparticle manipulation efficiency in both 2D and 3D platforms. The proposed method will open up new avenues in particle manipulation and benefit a variety of applications in cell separation, drug synthesis, analytical chemistry, and others. |
---|---|
ISSN: | 2470-1343 2470-1343 |
DOI: | 10.1021/acsomega.2c01783 |