Effects of Current on the Membrane and Boundary Layer Selectivity in Electrochemical Systems Designed for Nutrient Recovery

During electrochemical nutrient recovery, current and ion exchange membranes (IEM) are used to extract an ionic species of interest (e.g., ion) from a mixture of multiple ions. The species of interest (ion 1) has an opposing charge to the IEM. When ion 1 is extracted from the solution, the species f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACS sustainable chemistry & engineering 2022-07, Vol.10 (29), p.9411-9418
Hauptverfasser: Rodrigues, Mariana, Sleutels, Tom, Kuntke, Philipp, Buisman, Cees J. N., Hamelers, Hubertus V. M.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:During electrochemical nutrient recovery, current and ion exchange membranes (IEM) are used to extract an ionic species of interest (e.g., ion) from a mixture of multiple ions. The species of interest (ion 1) has an opposing charge to the IEM. When ion 1 is extracted from the solution, the species fractions at the membrane and the adjunct boundary layers are affected. Hence, the species transport through the electrochemical system (ES) can no longer be described as electrodialysis-like. A dynamic state is observed in the compartments, where the ionic species are recovered. When the boundary layer–membrane interface is depleted, the IEM is at maximum current. If the ES is operated at a current higher than the maximum current, the fluxes of both ion 1 and other competing ions, with the same charge (ion 2), occur. This means, for example, ion 1 will be recovered, and the concentration of ion 2 will build up in time. Therefore, a steady state is never reached. Ideally, to prevent the effect of limiting current at the boundary layer–membrane interface, ES for nutrient recovery should be operated at low currents.
ISSN:2168-0485
2168-0485
DOI:10.1021/acssuschemeng.2c01764