Photorefraction with Spot Vision Screener versus Visual Acuity Testing as Community-Based Preschool Vision Screening at the Age of 3.5 Years in Japan

Nationwide in Japan, a community-based vision-screening program in 3.5-year-old children is conducted in three steps: questionnaires and home visual acuity testing as the primary screening; visual acuity testing by nurses and pediatricians’ inspection in community health centers as the secondary scr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of environmental research and public health 2022-07, Vol.19 (14), p.8655
Hauptverfasser: Matsuo, Toshihiko, Matsuo, Chie, Kayano, Masami, Mitsufuji, Aya, Satou, Chiyori, Matsuoka, Hiroaki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nationwide in Japan, a community-based vision-screening program in 3.5-year-old children is conducted in three steps: questionnaires and home visual acuity testing as the primary screening; visual acuity testing by nurses and pediatricians’ inspection in community health centers as the secondary screening; and examinations by ophthalmologists as the tertiary screening. In this study, we introduced photorefraction with a Spot vision screener in addition to visual acuity testing to answer the clinical question of whether photorefraction could better detect eye diseases and potentially replace visual acuity testing. Photorefraction was performed on 813 consecutive 3.5-year-old children in a center. The children were sent to tertiary examinations, which were based on the Spot vision screener standard, in addition to the visual acuity testing standard: failure in either eye to pass 0.5 visual acuity in a center. A notice to visit ophthalmologists was issued for 95 children (11%), and documents with the diagnosis were sent back to the Heath Office for 76 children (80%). The rate of children with anisometropic or ametropic amblyopia or accommodative esotropia as treatment-requiring diseases was highest in cases of no pass at both standards (10/15 = 66%), and higher in cases of no pass only at the Spot vision screener standard (13/45 = 28%), compared with cases of no pass only at the visual acuity testing standard (6/33 = 18%, p = 0.0031). Photorefraction, in addition to visual acuity testing and inspection led to additional eye diseases detection at 3.5 years. Visual acuity testing at home would not be omitted in the introduction of photorefraction.
ISSN:1660-4601
1661-7827
1660-4601
DOI:10.3390/ijerph19148655