In Vivo Determination of the Human Corneal Elastic Modulus Using Vibrational Optical Coherence Tomography

PurposeTo determine the in vivo elastic modulus of the human cornea using vibrational optical coherence tomography (VOCT). MethodsVibrational analysis coupled with optical coherence tomography (OCT) was used to obtain the resonant frequency (RF) and elastic modulus of corneal structural components....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Translational vision science & technology 2022-07, Vol.11 (7), p.11-11
Hauptverfasser: Crespo, Marcos A., Jimenez, Hiram J., Deshmukh, Tanmay, Pulido, Jose S., Saad, Ahmed Saeed, Silver, Frederick H., Benedetto, Dominick A., Rapuano, Christopher J., Syed, Zeba A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PurposeTo determine the in vivo elastic modulus of the human cornea using vibrational optical coherence tomography (VOCT). MethodsVibrational analysis coupled with optical coherence tomography (OCT) was used to obtain the resonant frequency (RF) and elastic modulus of corneal structural components. VOCT corneal thickness values were measured using OCT images and correlated with corneal thickness determined with Pentacam (Oculus, Wetzlar, Germany). Moduli were obtained at two locations: central cornea (CC) and inferior cornea (IC). Measurements were obtained with and without anesthetic eye drops to assess their effect on the modulus measurements. ResultsVOCT thickness values correlated positively (R2 = 0.97) and linearly (y = 1.039x-16.89) with those of Pentacam. Five RF peaks (1-5) were present, although their presence was variable across eyes. The RF for peaks 1 to 5 in the CC and IC ranged from 73.5 ± 4.9 to 239 ± 3 Hz and 72.1 ± 6.3 to 238 ± 4 Hz, respectively. CC and IC moduli for peaks 1 to 5 ranged from 1.023 ± 0.104 to 6.87 ± 0.33 MPa and 0.98 ± 0.15 to 6.52 ± 0.79 MPa, respectively. Topical anesthesia did not significantly alter the modulus (P > 0.05 for all), except for peak 2 in the CC (P < 0.05). ConclusionsThis pilot study demonstrates the utility of VOCT as an in vivo, noninvasive technology to measure the elastic modulus in human corneas. The structural origin of these moduli is hypothesized based on previous reports, and further analyses are necessary for confirmation. Translational RelevanceThis work presents VOCT as a novel approach to assess the in vivo elastic modulus of the cornea, an indicator of corneal structural integrity and health.
ISSN:2164-2591
2164-2591
DOI:10.1167/tvst.11.7.11