Ultrasound Cyclo Plasty After Failed Glaucoma Surgery: Outcomes and Complications
Introduction The purpose of this study is to report the outcomes and complications of ultrasound cyclo plasty (UCP) after failed glaucoma surgery. Methods A retrospective case series included patients with previously failed glaucoma surgery who underwent UCP at King Abdul Aziz University Hospital, R...
Gespeichert in:
Veröffentlicht in: | Ophthalmology and Therapy 2022-08, Vol.11 (4), p.1601-1610 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
The purpose of this study is to report the outcomes and complications of ultrasound cyclo plasty (UCP) after failed glaucoma surgery.
Methods
A retrospective case series included patients with previously failed glaucoma surgery who underwent UCP at King Abdul Aziz University Hospital, Riyadh, Saudi Arabia, between 2016 and 2021. The main outcome measures were: intraocular pressure (IOP), number of antiglaucoma medications and presence of vision-threatening complications. The surgical outcome of each eye was based on the main outcome measures.
Results
Seventy eyes of 70 patients were included in the study. The mean follow-up period was 31.89 months (± 17.5). The IOP and the number of antiglaucoma medications decreased significantly from a mean of 23.91 mmHg (± 6.3) and 3.43 (± 0.8) to 17.88 mmHg (± 8.1) and 2.48 (± 1.3) and of 16.74 (± 7.9) and 2.11 (± 1.3) at the 12th and 24th months postoperatively, respectively (
p
|
---|---|
ISSN: | 2193-8245 2193-6528 |
DOI: | 10.1007/s40123-022-00538-3 |