Influence of Practitioner-Related Placement Variables on the Compressive Properties of Bulk-Fill Composite Resins-An In Vitro Clinical Simulation Study

Aims: To determine if restoration location and/or execution behavior force parameters have an influence on the mechanical properties of bulk-fill composite dental restorations. Methods: Pressure transducers were placed within each quadrant of dental mannequin jaws. Cylindrical molds were placed abov...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials 2022-06, Vol.15 (12), p.4305
Hauptverfasser: Brosh, Tamar, Davidovitch, Moshe, Berg, Avi, Shenhav, Aviran, Pilo, Raphael, Matalon, Shlomo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims: To determine if restoration location and/or execution behavior force parameters have an influence on the mechanical properties of bulk-fill composite dental restorations. Methods: Pressure transducers were placed within each quadrant of dental mannequin jaws. Cylindrical molds were placed above the transducers and filled with two bulk-fill composite materials, Filtek and Tetric, by four experienced dentists. Each dentist prepared five specimens per quadrant and material. The total placement time, mean force, number of peak forces (above 25 N), and mean peak(s) force during placement were measured. Then, the stiffness and maximal compressive strength of the specimens were determined while loading the specimens up to failure using a universal loading machine. Results: Placement time was affected by jaw (p < 0.004) and side (p < 0.029), with the shortest time demonstrated for the left side of the mandible. Force exerted during restoration placement was not normally distributed without differences in location (jaw) or material. A higher application force was found on the right side (p < 0.01). The number of peak forces was affected by side (p < 0.03), with less peaks on the left side. No significant differences were found in compressive strength when correlated to restoration location, participant, or material (p = 0.431). The stiffness values of Filtek (3729 ± 228 N/mm) were found to be 15% higher than Tetric (3248 ± 227 N/mm) (p < 0.005). No correlations were found between the compressive strength or stiffness and the amount of force applied during placement. Conclusions: The individual restoration material placement parameters did influence practitioner performance; however, these differences did not affect the mechanical properties of the final restoration.
ISSN:1996-1944
1996-1944
DOI:10.3390/ma15124305