Influence of Magnetic Water on Concrete Properties with Different Magnetic Field Exposure Times

The characteristics of a concrete mix are purely dependent on the hydration of cement that is carried forward by using the water quality used in the mix. Several researchers have focused on incorporating pozzolanic or nanomaterials to improve the hydration mechanisms and impart high strength to conc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials 2022-06, Vol.15 (12), p.4291
Hauptverfasser: Ramalingam, Malathy, Narayanan, Karuppasamy, Masilamani, Arivoli, Kathirvel, Parthiban, Murali, Gunasekaran, Vatin, Nikolai Ivanovich
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The characteristics of a concrete mix are purely dependent on the hydration of cement that is carried forward by using the water quality used in the mix. Several researchers have focused on incorporating pozzolanic or nanomaterials to improve the hydration mechanisms and impart high strength to concrete. A new technology has been introduced to improve the properties of concrete by magnetic-field-treated water (MFTW). Due to magnetization, water particles become charged and the molecules inside the water cluster decrease from 13 to 5 or 6, which eventually decreases the hardness of water, thus improving the strength of concrete when compared to the use of normal water (NW). In advanced construction techniques and practices, the application of Magnetic Water (MW) plays an important role in boosting physicochemical properties. This research work focused on evaluating the standards of water quality through physiochemical analysis, such as Electrical Conductivity (EC), Viscosity, pH, and Total Dissolved Solids (TDS) with the MW at different exposure periods (60 min (MW60), 45 min (MW45), 30 min (MW30), 15 min (MW15), and instant exposure (MWI)). Experiments were carried out to evaluate the fresh, hardened, and microstructural behavior of concrete made with magnetic water (MW) using a permanent magnet of PERMAG (N407) under a field intensity of 0.9 Tesla. In addition, optical properties such as X-ray Diffraction (XRD) and Ultraviolet (UV) absorption were considered for the MW60 mix to ensure water magnetization. Characterization methods such as Fourier Transform Infrared Spectroscopy (FT-IR), Thermogravimetric Analysis (TGA), and Scanning Electron Microscopy (SEM) were employed for NWC and MWC to quantify the hydrated products. From the results, it was observed that the magnetic effect on water characteristics showed significant improvement in the concrete properties with the increase in exposure duration. There were increments of 25.6% and 24.1% in workability and compressive strength, respectively, for the MW60 mix compared to normal water concrete (NWC).
ISSN:1996-1944
1996-1944
DOI:10.3390/ma15124291