C-reactive protein (CRP) as a biomarker of pulmonary exacerbation presentation and treatment response

•C-reactive protein (CRP) is a biomarker of systemic inflammation of interest in CF.•We studied CRP as a biomarker of response to pulmonary exacerbation (PEx) treatment.•CRP concentration at PEx diagnosis was a poor predictor of treatment response.•CRP change was an insensitive measure of lung funct...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cystic fibrosis 2022-07, Vol.21 (4), p.588-593
Hauptverfasser: VanDevanter, DR, Heltshe, SL, Skalland, M, West, NE, Sanders, DB, Goss, CH, Flume, PA
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•C-reactive protein (CRP) is a biomarker of systemic inflammation of interest in CF.•We studied CRP as a biomarker of response to pulmonary exacerbation (PEx) treatment.•CRP concentration at PEx diagnosis was a poor predictor of treatment response.•CRP change was an insensitive measure of lung function or symptom improvement. C-reactive protein (CRP) has been proposed as a biomarker for pulmonary exacerbation (PEx) diagnosis and treatment response. CRP >75mg/L has been associated with increased risk of PEx treatment failure. We have analyzed CRP measures as biomarkers for clinical response during the STOP2 PEx study (NCT02781610). CRP measures were collected at antimicrobial treatment start (V1), seven to 10 days later (V2), and two weeks after treatment end (V3). V1 log10CRP concentrations and log10CRP change from V1 to V3 correlations with clinical responses (changes in lung function and symptom score) were assessed by least squares regression. Odds of intravenous (IV) antimicrobial retreatment within 30 days and future PEx hazard associated with V1 and V3 CRP concentrations and V1 CRP >75 mg/L were studied by adjusted logistic regression and proportional hazards modeling, respectively. In all, 951 of 982 STOP2 subjects (92.7%) had CRP measures at V1. V1 log10CRP varied significantly by V1 lung function subgroup, symptom score quartile, and sex, but not by age subgroup. V1 log10CRP correlated moderately with log10CRP change at V3 (r2=0.255) but less so with lung function (r2=0.016) or symptom (r2=0.031) changes at V3. Higher V1 CRP was associated with greater response. CRP changes from V1 to V3 only weakly correlated with lung function (r2=0.061) and symptom (r2=0.066) changes. However, V3 log10CRP was associated with increased odds of retreatment (P = .0081) and future PEx hazard (P = .0114). Despite consistent trends, log10CRP change was highly variable with only limited utility as a biomarker of PEx treatment response.
ISSN:1569-1993
1873-5010
1873-5010
DOI:10.1016/j.jcf.2021.12.003