Urinary tract infections in children: Testing a novel, noninvasive, point‐of‐care diagnostic marker
Objectives Urinary neutrophil gelatinase‐associated lipocalin (uNGAL) appears highly accurate to identify urinary tract infections (UTIs) when obtained via catheterization. Our primary aim was to determine the agreement in uNGAL levels between paired catheter and bag urine specimens. Our secondary a...
Gespeichert in:
Veröffentlicht in: | Academic emergency medicine 2022-03, Vol.29 (3), p.326-333 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
Urinary neutrophil gelatinase‐associated lipocalin (uNGAL) appears highly accurate to identify urinary tract infections (UTIs) when obtained via catheterization. Our primary aim was to determine the agreement in uNGAL levels between paired catheter and bag urine specimens. Our secondary aim was to compare the diagnostic test characteristics of quantitative uNGAL, dipstick uNGAL (a potential point‐of‐care test), and urinalysis (UA).
Methods
This was a prospective study of febrile children < 24 months evaluated for UTIs. We evaluated quantitative uNGAL at a previously identified threshold of 39.1 ng/mL, dipstick uNGAL at its built‐in threshold of >50 ng/mL, and UA at standard thresholds for leukocyte esterase (LE). A positive urine culture was defined as >100,000 CFUs/mL of a pathogen.
Results
A total of 211 patients were included (10% with positive urine cultures); 116 had paired catheterized and bagged samples. The agreement between catheterized and bagged samples at a quantitative uNGAL cutoff of ≥39.1 ng/mL was 0.76 (95% confidence interval [CI] = 0.67 to 0.83) and 0.77 (95% CI = 0.68 to 0.84) at a uNGAL dipstick threshold of >50 ng/mL. The area under the receiver operating characteristic curve for uNGAL from a catheterized sample was 0.96 (95% CI = 0.89 to 1.00) compared to 0.93 (95% CI = 0.87 to –0.99) from a bagged sample. The sensitivities of catheterized sample quantitative and dipstick uNGAL (90.5%) were higher than UA at a LE threshold of ≥1+ (57.1%). Bagged‐sample uNGAL had lower quantitative and dipstick specificities (both 73.8%) than from catheterized samples (94.3% and 95.3% respectively), similar to UA.
Conclusions
uNGAL from bagged and catheterized samples showed insufficient agreement to be used interchangeably. The low specificity of uNGAL from bagged samples suggests that sampling technique affects uNGAL levels. |
---|---|
ISSN: | 1069-6563 1553-2712 |
DOI: | 10.1111/acem.14402 |