D-dimer in Marfan syndrome: effect of obstructive sleep apnea induced blood pressure surges

Aortic dissection and rupture are the major causes of premature death in persons with Marfan syndrome (MFS), a rare genetic disorder featuring cardiovascular, skeletal, and ocular impairments. We and others have found that obstructive sleep apnea (OSA) confers significant vascular stress in this pop...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of physiology. Heart and circulatory physiology 2022-05, Vol.322 (5), p.H742-H748
Hauptverfasser: Sowho, Mudiaga, Schneider, Hartmut, Jun, Jonathan, MacCarrick, Gretchen, Schwartz, Alan, Pham, Luu, Sgambati, Francis, Lima, Joao, Smith, Philip, Polotsky, Vsevolod, Neptune, Enid
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aortic dissection and rupture are the major causes of premature death in persons with Marfan syndrome (MFS), a rare genetic disorder featuring cardiovascular, skeletal, and ocular impairments. We and others have found that obstructive sleep apnea (OSA) confers significant vascular stress in this population and may accelerate aortic disease progression. We hypothesized that D-dimer, a diagnostic biomarker for several types of vascular injury that is also elevated in persons with MFS with aortic enlargement, may be sensitive to cardiovascular stresses caused by OSA. To test this concept, we recruited 16 persons with MFS without aortic dissection and randomized them to two nights of polysomnography, without (baseline) and with OSA treatment: continuous positive airway pressure (CPAP). In addition to scoring OSA by the apnea-hypopnea index (AHI), beat-by-beat systolic BP (SBP) and pulse-pressure (PP) fluctuations were quantified. Morning blood samples were also assayed for D-dimer levels. In this cohort (male:female, 10:6; age, 36 ± 13 yr; aortic diameter, 4 ± 1 cm), CPAP eliminated OSA (AHI: 20 ± 17 vs. 3 ± 2 events/h, = 0.001) and decreased fluctuations in SBP (13 ± 4 vs. 9 ± 3 mmHg, = 0.011) and PP (7 ± 2 vs. 5 ± 2 mmHg, = 0.013). CPAP also reduced D-dimer levels from 1,108 ± 656 to 882 ± 532 ng/mL ( = 0.023). Linear regression revealed a positive association between the maximum PP during OSA and D-dimer in both the unadjusted ( = 0.523, = 0.038) and a model adjusted for contemporaneous aortic root diameter ( = 0.733, = 0.028). Our study revealed that overnight CPAP reduces D-dimer levels commensurate with the elimination of OSA and concomitant hemodynamic fluctuations. Morning D-dimer measurements together with OSA screening might serve as predictors of vascular injury in MFS. What is New? Surges in blood pressure caused by obstructive sleep apnea during sleep increase vascular stress and D-dimer levels in Marfan syndrome. Elevations in D-dimer can be lowered with CPAP. What is Noteworthy? D-dimer levels might serve as a marker for determining the significance of obstructive sleep apnea in persons with Marfan syndrome. D-dimer or obstructive sleep apnea screening is a potential method to identify persons with Marfan syndrome at risk for adverse cardiovascular events.
ISSN:0363-6135
1522-1539
DOI:10.1152/ajpheart.00004.2022