The Feasibility of Surface Electromyography in Monitoring Orbicularis Oculi Recovery after Anterior Approach Levator Aponeurosis Advancement
In this article, we propose a new application for eyelid surface electromyography (sEMG). By placing the electrode in the mid-pretarsal area of the upper eyelid, one can easily perform a fast examination and achieve repeatable results. We believe that this technique may increase the feasibility of e...
Gespeichert in:
Veröffentlicht in: | Journal of clinical medicine 2022-01, Vol.11 (3), p.731 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this article, we propose a new application for eyelid surface electromyography (sEMG). By placing the electrode in the mid-pretarsal area of the upper eyelid, one can easily perform a fast examination and achieve repeatable results. We believe that this technique may increase the feasibility of eyelid sEMG in clinical practice.
126 sEMG examinations of the upper eyelid were performed by using the above-described method. Thirty-nine controls and 29 ptotic patients were enrolled. The controls underwent one measurement while the ptotic patients were employed for four sessions: Before anterior approach levator aponeurosis advancement (LAA), 2 weeks, 3 months, and more than 6 months after surgery. The relaxation and maximal contraction of the orbicularis oculi muscle (OOM) using root mean square (RMS) values were measured.
The results showed a statistically significant decrease in RMS values of the maximal contraction of the OOM 2 weeks after surgery (
< 0.05) and 3 months after surgery (
= 0.03). Six months postoperatively, there were no statistically significant differences in OOM activity compared to preoperative values (
= 0.2).
Eyelid sEMG may be a useful diagnostic tool in post-operative OOM recovery monitoring. sEMG parameters of the maximal contraction of the OOM normalize within 6 months after anterior approach LAA. Electrode placement in the mid-pretarsal area of the upper eyelid offers several advantages and therefore may enhance the feasibility of sEMG in clinical practice. |
---|---|
ISSN: | 2077-0383 2077-0383 |
DOI: | 10.3390/jcm11030731 |