An original method of simulating the articular cartilage in the context of in vitro biomechanical studies investigating the proximal femur

Biomechanical testing is a necessity given the development of novel implants used in the osteosynthesis of hip fractures. The purpose of biomechanical testing is to recreate realistic conditions similar to the conditions. Although biomechanical testing of hip arthroplasty has been standardized since...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental and therapeutic medicine 2022-03, Vol.23 (3), p.202, Article 202
Hauptverfasser: Gheorghevici, Teodor Stefan, Carata, Eugen, Sirbu, Paul-Dan, Alexa, Ovidiu, Poroh, Manuela-Gabi, Filip, Alexandru, Forna, Norin, Puha, Bogdan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Biomechanical testing is a necessity given the development of novel implants used in the osteosynthesis of hip fractures. The purpose of biomechanical testing is to recreate realistic conditions similar to the conditions. Although biomechanical testing of hip arthroplasty has been standardized since the 1970s, there is no consensus at present on testing methodology for osteosynthesis of hip fractures. Most biomechanical studies examining the fractures of the proximal femur in order to optimize implants opt for loading the bone-implant ensemble directly on the femoral head or using a metallic loading part. This loading technique fails to perform a mechanical stress distribution similar to conditions, which could alter the outcome. The present study aimed to design loading/unloading cups with mechanical properties that resemble those of the cartilage at the hip level. Through the impression and scanning of the cast models obtained, a digital 3D model was created in STL format and this was processed in order to obtain the computer numerical control (CNC) trajectories of the printing head. For prototyping using additive manufacturing technology, a thermoplastic polymer with biochemical properties, such as tensile strength, that resemble those of the adult hip and a Stratasys FORTUS 250 mc CNC machine were used. Loading/unloading cups with similar anatomy and biomechanical forces compared with those of the adult hip were created, which allowed the experimental simulation of the conditions during walking.
ISSN:1792-0981
1792-1015
DOI:10.3892/etm.2022.11125