Comparison of shear bond strength of CAD/CAM and conventional heat-polymerized acrylic resin denture bases to auto-polymerized and heat-polymerized acrylic resins after aging
The aim of this study was to investigate the shear bond strength of CAD/CAM and conventional heat polymerized acrylic resin denture bases bonded to self-cured and heat-cured acrylic resins after aging. A total of 40 cubic specimens were fabricated from conventional heat-polymerized and CAD/CAM dentu...
Gespeichert in:
Veröffentlicht in: | Journal of clinical and experimental dentistry 2022-01, Vol.14 (1), p.e72-e78 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to investigate the shear bond strength of CAD/CAM and conventional heat polymerized acrylic resin denture bases bonded to self-cured and heat-cured acrylic resins after aging.
A total of 40 cubic specimens were fabricated from conventional heat-polymerized and CAD/CAM denture base resins. Denture base resin specimens in each group were divided into two subgroups (n=10) in which they were bonded to either a heat-cured (HC) or a self-cured (SC) reline resin. Subsequently, the specimens were subjected to thermocycling. Then the shear bond strength (SBS) of specimens was measured using the universal testing machine. After testing, modes of failure were examined using light microscopy. The results were submitted to statistical analysis.
Mann-Whitney test showed that in each group of denture base materials, specimens bonded to HC reline resin had significantly higher SBS than those bonded to SC reline resin ( |
---|---|
ISSN: | 1989-5488 1989-5488 |
DOI: | 10.4317/JCED.59097 |