Spanish Cardiac Catheterization and Coronary Intervention Registry. 30th Official Report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990-2020) in the year of the COVID-19 pandemic
The Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) presents its annual activity report for 2020, the year of the coronavirus disease (COVID-19) pandemic. All Spanish centers with catheterization laboratories were invited to participate. Data were collected onlin...
Gespeichert in:
Veröffentlicht in: | Revista española de cardiología (English ed.) 2021-12, Vol.74 (12), p.1095-1105 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) presents its annual activity report for 2020, the year of the coronavirus disease (COVID-19) pandemic.
All Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company, together with the members of the ACI-SEC.
A total of 123 centers participated (4 more than 2019), of which 83 were public and 40 were private. Diagnostic coronary angiograms decreased by 9.4%, percutaneous coronary interventions by 10.1%, primary percutaneous coronary interventions by 4.1%, transcatheter aortic valve replacements by 0.9%, and left atrial appendage closure by 8.3%. The only procedures that increased with respect to previous years were edge-to-edge mitral valve repair (13.8%) and patent foramen ovale closure (19.4%). The use of pressure wire (5.5%), intravascular imaging devices and plaque preparation devices decreased (with the exception of lithotripsy, which increased by 62%).
In the year of the COVID-19 pandemic, the registry showed a marked drop in activity in all procedures except for percutaneous mitral valve repair and patent foramen ovale closure. This decrease was less marked than previously described, suggesting a rebound in interventional activity after the first wave.
La Asociación de Cardiología Intervencionista de la Sociedad Española de Cardiología (ACI-SEC) presenta su informe anual de actividad de 2020, año de la pandemia de la COVID-19.
Se invitó a participar a todos los centros españoles con sala de hemodinámica. La recogida de datos se realizó por vía telemática y una empresa externa, junto con los miembros de la ACI-SEC, llevó a cabo su análisis.
Participaron 123 centros (4 más que el año previo), 83 públicos y 40 privados. Se observó una reducción del 9,4% de coronariografías, el 10,1% de intervenciones coronarias percutáneas, el 4,1% de angioplastias primarias, el 0,9% de válvulas aórticas transcatéter y el 8,3% de cierre de orejuelas. Los únicos procedimientos que se incrementaron con respecto a años previos fueron la reparación mitral con clips (13,8%) y el cierre del foramen oval permeable (19,4%). En cuanto a los dispositivos, disminuyeron las guías de presión (5,5%), la imagen intravascular y los dispositivos de preparación de placa (a excepción de la litotricia, que aumentó un 62%).
El registro en el año de la pandemia de la COVID-19 demuestra una marcada caída en la activida |
---|---|