Original Designed Uniportal‐Bichannel Spinal Endoscopic System (UBiSES) for Foraminoplasty in Percutaneous Endoscopic Transforaminal Discectomy

Objective The study introduced uniportal‐bichannel spinal endoscopic system (UBiSES) and explored the feasibility of applying UBiSES to conduct lumbar foraminoplasty in percutaneous endoscopic transforaminal discectomy (PETD). Methods This is a cohort study. 36 patients confirmed as L5/S1 lumbar dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Orthopaedic surgery 2021-10, Vol.13 (7), p.1987-1999
Hauptverfasser: Zhou, Zhi, Ni, Hai‐jian, Hu, Shuo, Fan, Yun‐shan, Wang, Chuan‐feng, Chen, Xin, Zhu, Yan‐jie, Li, Gang, Liu, Fei, Feng, Chao‐bo, He, Shi‐sheng
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective The study introduced uniportal‐bichannel spinal endoscopic system (UBiSES) and explored the feasibility of applying UBiSES to conduct lumbar foraminoplasty in percutaneous endoscopic transforaminal discectomy (PETD). Methods This is a cohort study. 36 patients confirmed as L5/S1 lumbar disc herniation (LDH) in our hospital from March, 2019 to November, 2019 were enrolled. 36 patients were divided into two groups named the UBiSES group (n = 18, male: female = 8:10) and the TESSYS group (n = 18, male: female = 10:8). The average age of the UBiSES group and the TESSYS group were 40.94 ± 12.39 years old and 39.78 ± 13.02 years old respectively. PETD via uniportal‐bichannel foraminoplasty assisted by UBiSES was adopted on the UBiSES group while PETD via conventional foraminoplasty was performed on the TESSYS group. One experienced surgeon with more than 4000 cases of lumbar surgery performed PETD on all patients. The demographic data, the duration of working cannula placement (minutes), decompression time (minutes), radiation exposure time (seconds), complications, Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) scores and modified MacNab criteria were recorded and analyzed. The magnetic resonance imaging (MRI) and computed tomography (CT) were conducted to evaluate the radiographic improvement. Results PETD via lumbar foraminoplasty was successfully performed in all cases. The follow‐up points were 3 months, 6 months, and 12 months. The average follow‐up period of all patients was 15.78 ± 2.29 months. There was no statistic difference in age (P = 0.81), sex (P = 0.51) and follow‐up (P = 0.14) between two groups. The duration of working cannula placement was 19.08 ± 2.30 min in the UBiSES group and 24.90 ± 4.71 min in the TESSYS group and there was significant difference between two groups (P 
ISSN:1757-7853
1757-7861
DOI:10.1111/os.13050