A Weaving Rip-Stop Technique Leads to a Significantly Increased Load to Failure and Reduction in Suture-Tendon Cut-Through in a Biomechanical Model of Rotator Cuff Repair

To present an alternative arthroscopic rip-stop technique with a single suture tape weaved through the tendon from anterior to posterior and to biomechanically test its strength against a control technique consisting of a single-row repair with simple sutures. This was a controlled biomechanical stu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arthroscopy, Sports Medicine, and Rehabilitation Sports Medicine, and Rehabilitation, 2021-10, Vol.3 (5), p.e1263-e1272
Hauptverfasser: Neeley, Ryan A., Diaz, Miguel A., Gorman, R. Allen, Frankle, Mark A., Mighell, Mark A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To present an alternative arthroscopic rip-stop technique with a single suture tape weaved through the tendon from anterior to posterior and to biomechanically test its strength against a control technique consisting of a single-row repair with simple sutures. This was a controlled biomechanical study. Dissection and harvesting of the supraspinatus muscle-tendon unit were performed along the cable in 9 matched-pair cadaveric shoulders. Samples were divided into 2 groups: simple suture repair only (SSR) and simple suture repair with rip-stop (SSPR). Biomechanical testing was performed with an initial preload, followed by cyclic loading and then ramp to failure. Peak-to-peak displacement, stiffness (in newtons per millimeter), load at failure (in newtons), and failure mechanism were recorded. Data were compared using the paired-sample t test. The average peak-to-peak displacement for SSR samples was not significantly different from that of SSPR samples (P = .96). Similarly, elongation in the SSR and SSPR groups was not significantly different (P = .82). Stiffness was significantly different between the SSR and SSPR groups (P = .0054): SSR samples were less stiff than SSPR samples. Moreover, SSR samples failed at significantly lower forces than did SSPR samples (P = .028). A larger percentage of failures occurred due to tendon cut-through among SSR samples versus suture breakage among SSPR samples. An alternative rip-stop technique is presented in this biomechanical model that may assist surgeons to better deal with difficult rotator cuff repairs. Weaving a suture tape as a rip-stop can increase stiffness, achieve higher failure loads when compared with simple suture repair with no rip-stop, and reduce tendon cut-through. This study provides insight into a variation of rip-stop stitch techniques that may help solve the clinical problem of failure occurring at the suture-tendon interface, specifically tendon cut-through.
ISSN:2666-061X
2666-061X
DOI:10.1016/j.asmr.2021.04.005