Fast dynamic brain PET imaging using stochastic variational prediction for recurrent frame generation

Purpose We assess the performance of a recurrent frame generation algorithm for prediction of late frames from initial frames in dynamic brain PET imaging. Methods Clinical dynamic 18F‐DOPA brain PET/CT studies of 46 subjects with ten folds cross‐validation were retrospectively employed. A novel sto...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2021-09, Vol.48 (9), p.5059-5071
Hauptverfasser: Sanaat, Amirhossein, Mirsadeghi, Ehsan, Razeghi, Behrooz, Ginovart, Nathalie, Zaidi, Habib
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose We assess the performance of a recurrent frame generation algorithm for prediction of late frames from initial frames in dynamic brain PET imaging. Methods Clinical dynamic 18F‐DOPA brain PET/CT studies of 46 subjects with ten folds cross‐validation were retrospectively employed. A novel stochastic adversarial video prediction model was implemented to predict the last 13 frames (25–90 minutes) from the initial 13 frames (0–25 minutes). The quantitative analysis of the predicted dynamic PET frames was performed for the test and validation dataset using established metrics. Results The predicted dynamic images demonstrated that the model is capable of predicting the trend of change in time‐varying tracer biodistribution. The Bland‐Altman plots reported the lowest tracer uptake bias (−0.04) for the putamen region and the smallest variance (95% CI: −0.38, +0.14) for the cerebellum. The region‐wise Patlak graphical analysis in the caudate and putamen regions for eight subjects from the test and validation dataset showed that the average bias for Ki and distribution volume was 4.3%, 5.1% and 4.4%, 4.2%, (P‐value
ISSN:0094-2405
2473-4209
DOI:10.1002/mp.15063