Importance of anti-SARS-CoV-2 assay antigenic composition as revealed by the results of the Belgian external quality assessment (EQA) scheme

●Sciensano and its department Quality of Laboratories routinely organizes external quality assessment as a part of the mandatory external quality assessment program for SARS-CoV-2 serology in Belgium.●Sample IS/17575 generated highly discordant results.●The importance of the choice of antigenic comp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic microbiology and infectious disease 2022-02, Vol.102 (2), p.115561-115561, Article 115561
Hauptverfasser: Moerman, Alena, Vernelen, Kris, China, Bernard, Capron, Arnaud, Bossche, Dorien Van Den, Mariën, Joachim, Ariën, Kevin K., Van Acker, Jos, Delforge, Marie-Luce, Reynders, Marijke, Boel, An, Depypere, Melissa, Van Gasse, Natasja, Vijgen, Sara, Brauner, Jonathan, Dujardin, Barbara, Padalko, Elizaveta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:●Sciensano and its department Quality of Laboratories routinely organizes external quality assessment as a part of the mandatory external quality assessment program for SARS-CoV-2 serology in Belgium.●Sample IS/17575 generated highly discordant results.●The importance of the choice of antigenic composition.●Antibody response against the N 184 protein appears to wane post-infection.●Difference in sensitivity of RBD 192 vs S1 vs S protein based immunoassays. We report on sample IS/17575 since it generated highly divergent results in the Belgian SARS-CoV-2 serology external quality assessment scheme. Sample IS/17575 was serum originating from a 30 years old male patient. 124 diagnostic laboratories analysed this sample. A total of 168 results was returned (including 5 doubles). Overall, 38 were positive. All tests against S1 were positive except the Euroimmun IgG ELISA and the Ortho clinical Diagnostics VITROS IgG CLIA. All tests against S1/S2 (Liaison, Diasorin) resulted in a signal above cutoff. Assays against RBD, mostly generate a negative result. An exception are the Wantai SARS-CoV-2 ELISA's. All tests targeting N protein were negative. The survey shows, when >6 months post-infection, assays targeting at least S1, and preferably S1 combined with S2, are the most sensitive. This finding accentuates the necessity of external quality assessment schedules and importance of antigenic composition of serologic SARS-CoV-2 assays.
ISSN:0732-8893
1879-0070
DOI:10.1016/j.diagmicrobio.2021.115561