The effects of gel pad thickness on the evaluation of skin structures using ultrasonography in normal dogs
Gel pads are commonly used in skin ultrasonography; however, the effects of their thickness are unknown. This study investigated the effects of pad thickness on measurements of skin thickness in 10 beagle dogs. Sonograms to measure neck skin thickness were captured without pads and using pads with t...
Gespeichert in:
Veröffentlicht in: | Journal of Veterinary Medical Science 2021, Vol.83(9), pp.1472-1475 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Gel pads are commonly used in skin ultrasonography; however, the effects of their thickness are unknown. This study investigated the effects of pad thickness on measurements of skin thickness in 10 beagle dogs. Sonograms to measure neck skin thickness were captured without pads and using pads with thicknesses of 3, 5, 10, and 20 mm. Without pads, acoustic shading was observed due to air bubbles in the coupling gel. With 20-mm pads, echogenic artifacts were observed on the skin surface. Entry echo with 20-mm pads was significantly higher than with 3-mm pads. This suggests that visibility of the skin structure could be affected when a gel pad is not used or when a thick gel pad is selected. |
---|---|
ISSN: | 0916-7250 1347-7439 |
DOI: | 10.1292/jvms.21-0086 |