Noninvasive Ventilatory Support of Patients with COVID-19 outside the Intensive Care Units (WARd-COVID)

(778/909; 85%) patients were treated with continuous positive airway pressure (CPAP), which was delivered by helmet in 617 (68%) patients. NIV failed in 300 patients (37.6%), whereas 498 (62.4%) patients were discharged alive without intubation. Overall mortality was 25%. NIV failure occurred in 152...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of the American Thoracic Society 2021-06, Vol.18 (6), p.1020-1026
Hauptverfasser: Bellani, Giacomo, Grasselli, Giacomo, Cecconi, Maurizio, Antolini, Laura, Borelli, Massimo, De Giacomi, Federica, Bosio, Giancarlo, Latronico, Nicola, Filippini, Matteo, Gemma, Marco, Giannotti, Claudia, Antonini, Benvenuto, Petrucci, Nicola, Zerbi, Simone Maria, Maniglia, Paolo, Castelli, Gian Paolo, Marino, Giovanni, Subert, Matteo, Citerio, Giuseppe, Radrizzani, Danilo, Mediani, Teresa S., Lorini, Ferdinando Luca, Russo, Filippo Maria, Faletti, Angela, Beindorf, Andrea, Covello, Remo Daniel, Greco, Stefano, Bizzarri, Marta M., Ristagno, Giuseppe, Mojoli, Francesco, Pradella, Andrea, Severgnini, Paolo, Da Macallè, Marta, Albertin, Andrea, Ranieri, V. Marco, Rezoagli, Emanuele, Vitale, Giovanni, Magliocca, Aurora, Cappelleri, Gianluca, Docci, Mattia, Aliberti, Stefano, Serra, Filippo, Rossi, Emanuela, Valsecchi, Maria Grazia, Pesenti, Antonio, Foti, Giuseppe
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:(778/909; 85%) patients were treated with continuous positive airway pressure (CPAP), which was delivered by helmet in 617 (68%) patients. NIV failed in 300 patients (37.6%), whereas 498 (62.4%) patients were discharged alive without intubation. Overall mortality was 25%. NIV failure occurred in 152/284 (53%) patients with an arterial oxygen pressure (PaO2 )/fraction of inspired oxygen (FIO2 ) ratio ,150 mm Hg. Higher C-reactive protein and lower PaO2 /FIO2 and platelet counts were independently associated with increased risk of NIV failure. Conclusions: The use of NIV outside the ICUs was common in COVID-19, with a predominant use of helmet CPAP, with a rate of success .60% and close to 75% in full-treatment patients. C-reactive protein, PaO2 /FIO2 , and platelet counts were independently associated with increased risk of NIV failure.
ISSN:2329-6933
2325-6621
DOI:10.1513/AnnalsATS.202008-1080OC